LV429682Main Range Compact Product name Compact NSX Product or component type Circuit breaker Device short name Compact NSX100H Device application Distribution Poles description 4P Protected poles description 3t Neutral position Left Network type AC Network frequency 50 60 Hz [In] rated current 100 A at 40 C [Ui] rated insulation voltage 800 V AC 50 60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ue] rated operational voltage 690 V AC 50 60 Hz Breaking
Main
| Range | Compact |
| Product name | Compact NSX |
| Product or component type | Circuit breaker |
| Device short name | Compact NSX100H |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 3t |
| Neutral position | Left |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [In] rated current | 100 A at 40 °C |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Breaking capacity code | H 70 kA 415 V AC |
| Breaking capacity | 10 kA at 600 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 65 kA at 480 V AC 50/60 Hz conforming to UL 508 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Pollution degree | 3 conforming to IEC 60664-1 |
Complementary
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Auxiliary contact composition | Without |
| Mechanical durability | 50000 cycles |
| Electrical durability | 10000 cycles 690 V In conforming to IEC 60947-2 20000 cycles 690 V In/2 conforming to IEC 60947-2 30000 cycles 440 V In conforming to IEC 60947-2 50000 cycles 440 V In/2 conforming to IEC 60947-2 |
| Connection pitch | 35 mm |
| Local signalling | Positive contact indication |
| Neutral protection setting | No protection (3t) |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 63 A at 40 °C |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| [tr] long-time delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Short-time pick-up adjustment type Isd | Fixed |
| [Isd] short-time pick-up adjustment range | 500 A |
| Short-time delay adjustment type | Fixed |
| Height | 161 mm |
| Width | 140 mm |
| Depth | 86 mm |
| Net weight | 2.4 kg |
| Compatibility code | NSX100 |
Environment
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Standards | EN/IEC 60947 UL 508 |
| Product certifications | Marine CCC EAC |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -55…85 °C |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.1 ★★★★★
Based on 1703 reviews
Sort
Product Reviews
★★★★★ 5
Small but mighty
Size: 5.25” Woofer
Great sound. I can turn my stereo up loader than I care to listen to it and notice no distortion.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 20, 2026
★★★★★ 5
Solid choice for fuse holder
Size: 300A Fuse Holder
It’s awesome, solid connections for running 0 gauge wire. No issues after using for months! Might upgrade to using 0 gauge wire ferrules to use with this but for now everything is working well.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 14, 2026
★★★★★ 5
Would buy again
Size: 300A Fuse Holder
Works as described
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 13, 2026
★★★★★ 5
I can wire my 0gage wre finally
Size: 300A Fuse Holder
The speed of service and delivery fused at different Amps voltage to purchase appearance is always a great addition and skar audio is always a head of the game I love skar audio I have been running their RP series amps I have all of them except the 4500.1 I bought this for my 07 Wolfsburg jetta with a 15 dual 2ohm down to 1ohm with the RP 3500.1 and it slumps and hits so low the skar box foe my single 15evl series..is tuned to 30htz..n when it hits that level and lower man u know it ..o call it the 23htz (23hurter)..explosive always excellent quality and functionality thanks 😊
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 28, 2025
★★★★★ 5
Top notch
Size: 300A Fuse Holder
Very good quality
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 8, 2026