LC1F500F7Main Range TeSys Product name TeSys F Product or component type Contactor Device short name LC1F Contactor application Resistive load Motor control Utilisation category AC 1 AC 3 AC 4 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage <= 1000 V AC 50 60 Hz <= 460 V DC [Ie] rated operational current 700 A (at <40 C) at <= 440 V AC AC 1 500 A (at <55 C) at <= 440 V AC AC 3 Motor power kW 250 kW at 380 400 V AC 50 60
Main
| Range | TeSys |
| Product name | TeSys F |
| Product or component type | Contactor |
| Device short name | LC1F |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-1 AC-3 AC-4 |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
| [Ie] rated operational current | 700 A (at <40 °C) at <= 440 V AC AC-1 500 A (at <55 °C) at <= 440 V AC AC-3 |
| Motor power kW | 250 kW at 380...400 V AC 50/60 Hz (AC-3) 280 kW at 415 V AC 50/60 Hz (AC-3) 295 kW at 440 V AC 50/60 Hz (AC-3) 355 kW at 500 V AC 50/60 Hz (AC-3) 335 kW at 660...690 V AC 50/60 Hz (AC-3) 335 kW at 1000 V AC 50/60 Hz (AC-3) 147 kW at 220...230 V AC 50/60 Hz (AC-3) 80 kW at 400 V AC 50/60 Hz (AC-4) |
| [Uc] control circuit voltage | 110 V AC 40...400 Hz |
Complementary
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 700 A (at 40 °C) |
| Rated breaking capacity | 4000 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 4200 A 40 °C - 10 s 3200 A 40 °C - 30 s 2400 A 40 °C - 1 min 1500 A 40 °C - 3 min 1200 A 40 °C - 10 min |
| Associated fuse rating | 500 A aM at <= 440 V 800 A gG at <= 440 V |
| Average impedance | 0.18 mOhm - Ith 700 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
| Power dissipation per pole | 88 W AC-1 45 W AC-3 |
| Mounting support | Plate |
| Standards | IEC 60947-4-1 JIS C8201-4-1 IEC 60947-1 EN 60947-1 EN 60947-4-1 |
| Product certifications | UL CSA ABS DNV LROS (Lloyds register of shipping) RMRoS RINA CB BV |
| Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 240 mm² Power circuit: bolted connection |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) |
| Inrush power in VA | 1100 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 18 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
| Heat dissipation | 18 W |
| Operating time | 40...65 ms closing 100...170 ms opening |
| Mechanical durability | 10 Mcycles |
| Maximum operating rate | 2400 cyc/h 55 °C |
| Compatibility code | LC1F |
| Motor power range | 250…500 kW at 380…440 V 3 phases 110…220 kW at 380…440 V 3 phases 110…220 kW at 200…240 V 3 phases 250…500 kW at 480…500 V 3 phases |
| Motor starter type | Direct on-line contactor |
| Contactor coil voltage | 110 V AC standard |
Environment
| IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
| Protective treatment | TH |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -60…80 °C |
| Permissible ambient air temperature around the device | -40…70 °C |
| Operating altitude | 3000 m without |
| Height | 238 mm |
| Width | 233 mm |
| Depth | 232 mm |
| Net weight | 11.35 kg |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Under investigation |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.5 ★★★★★
Based on 134 reviews
Sort
Product Reviews
★★★★★ 5
OEM is always the answer
No reason not to go OEM for this! Came with every possible gasket and seal I could need. Specifically for my Alpha One Gen 1 it took maybe 25-30 min to completely install.
While you’re there check the base plate for wear and the other surrounding items like your water tube. Rather keep the lower unit off for an extra day to get another part than a catastrophic failure.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 9, 2025
★★★★★ 5
Husbands things
My husband bought this. I don’t know much about it but he has zero complaints. He bought it for a boat. He has fixed up 2 boats, sold one & we kept the other. So he apparently knows what to buy & how to use it.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 6, 2025
★★★★★ 4
Amazon is easy and fast . No problems the oarts was exactly as described.
liked that everything was in one bag . and could make sure everything was changed .
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 3, 2020
★★★★★ 5
Stay cool
Just what I needed, super fast shipping
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 19, 2025
★★★★★ 5
Outboard is Cooling
The repair kit arrived on time as scheduled. The kit contained everything needed to replace the Mercury 175 OptiMax impeller. The engine is cooling now and we are back on the water without issue. Easy replacement.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 5, 2023