Human CCDC39 ELISA Kit
SKU: 6590557447

Human CCDC39 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 4 - Jul 9

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Human CCDC39 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.
4. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against coiled-coil domain-containing protein 39 (CCDC39). After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of coiled-coil domain-containing protein 39 (CCDC39) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Human
Synonym Human Coiled-coil domain-containing protein 39 ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Coiled-Coil Domain Containing 39 is a protein-coding gene. Diseases associated with CCDC39 include ciliary dyskinesia, primary, 14, and primary ciliary dyskinesia. Gene Ontology (GO) annotations associated with this gene include nucleotide binding.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.156-10 ng/mL
Applications Serum, plasma, tissue homogenates and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 6590557447

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 217 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
R
Verified Purchase
Rodolfo Costa
Alexandria, US
★★★★★ 5
A Thoughtful Look at Healing Beyond the Physical
Format: Kindle
The Energy Code invites you to slow down and view health from a completely different angle, rather than focusing only on symptoms or surface-level fixes. The book presents a deeper question: What if the body is responding to something happening beneath the surface? The book doesn't dismiss conventional medicine or make bold claims; it simply opens the door to another layer of understanding. It explores how emotional patterns, energy imbalances, and unresolved stress might show up physically, and it does so in a way that feels thoughtful rather than extreme. The symptom guide encourages reflection, not fear, and helps you see possible connections between what your body is experiencing and what might be going on internally. Even if you don't agree with every idea, it's hard not to find moments that make you pause and think. If you're open to holistic perspectives and want to explore healing from the inside out, The Energy Code offers an insightful and reflective place to start.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 3, 2026
E
Verified Purchase
Em D
Bozeman, US
★★★★★ 5
Bridge Between Energy Work and Nervous System Healing
Format: Kindle
I’ve been trained in Reiki and am certified in breathwork, which drew me to this book. The connection the author makes between suppressed emotions, nervous system dysregulation, and physical symptoms is impressive. In my own work with energy and breath, I’ve seen firsthand how unresolved experiences become stored in the body. This book explains why that happens. The explanation of energetic blockages and the chakra system are accurate and explained well. There is an emphasis on safety and nervous system support, which is essential in breathwork and trauma-informed healing. The symptom guide is also thorough and helps you decide where and what you need to work on. Highly recommended.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 21, 2026
B
Verified Purchase
Bryan Driscoll
Charlottesville, US
★★★★★ 4
What Your Body Is Telling You
Format: Kindle
This book makes a strong impression right from the start. The tone is calm and steady, and it never feels like it’s trying to scare you or sell quick answers. Instead, the author takes a simple, grounded approach to understanding physical sensations and why they show up in daily life. The book connects stress, emotions, and the body. These ideas can sound complicated, but here they’re explained in plain language that makes sense right away. You don’t need any special background to follow along, just a willingness to pay attention. The book doesn’t preach or push a strict method. It encourages awareness rather than control, which feels refreshing. It gives you space to reflect and notice patterns without judgment. Overall, this is a thoughtful and approachable read that feels supportive without being soft.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 18, 2026
V
Verified Purchase
Val
Lexington, US
★★★★★ 5
empowering
Format: Kindle
The Energy Code offers a thought-provoking look at healing from a mind-body perspective. I appreciated how it encourages readers to see symptoms not as enemies, but as signals worth listening to. The breathwork and grounding exercises were practical and surprisingly calming. That said, some concepts lean heavily into spiritual language, which may not resonate with everyone. Overall, it’s an empowering read if you’re open to exploring healing beyond traditional medicine and want to take a more active role in understanding your body.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 13, 2026
T
Verified Purchase
TW
Lexington, US
★★★★★ 5
Great Resource for Holistic Healing
Format: Kindle
When I came across this book it reminded me of Louise Hayes “You Can Heal Your Life”. It addresses many issues that manifest physically in the body and how to release it by releasing the emotional energetic aspect that relates to it by knowing the cause, it provides a solution along with key words for energetic healing and a strengthening affirmation and tips. Some ailments or issues listed I was surprised to see as one would think you can’t do anything about it, but you can - and the author makes clear from the beginning this book is not a substitute for medical advice or treatment but rather to complement it and to provide alternative options for those who want to take a holistic approach.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 21, 2025

recommand products