LUB12
SKU: 36758442667

LUB12

Sale price$105.20 Regular price$116.89
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 6 - Jul 11

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

LUB12Main Range TeSys Product name TeSys U Device short name LUB Product or component type Non reversing power base Device application Motor Poles description 3P Suitability for isolation Yes [Ith] conventional free air thermal current 12 A Utilisation category AC 44 AC 43 AC 41 [Uc] control circuit voltage 24 V AC 50 60 Hz 24 V DC 48 V AC 50 60 Hz 48 72 V DC 110 220 V DC 110 240 V AC 50 60 Hz Complementary Auxiliary contact composition 1 NO + 1 NC

Main
Range TeSys
Product name TeSys U
Device short name LUB
Product or component type Non reversing power base
Device application Motor
Poles description 3P
Suitability for isolation Yes
[Ith] conventional free air thermal current 12 A
Utilisation category AC-44
AC-43
AC-41
[Uc] control circuit voltage 24 V AC 50/60 Hz
24 V DC
48 V AC 50/60 Hz
48...72 V DC
110...220 V DC
110...240 V AC 50/60 Hz
Complementary
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
[Ue] rated operational voltage 230 V
440 V
500 V
690 V
Network frequency 40...60 Hz
[Ie] rated operational current 12 A at <= 440 V
12 A at 500 V
9 A at 690 V
[Ics] rated service breaking capacity 10 kA at 500 V
4 kA at 690 V
50 kA at 230 V
50 kA at 440 V
Typical current consumption 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
150 mA at 24 V DC I maximum while closing with LUCM
280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V DC I rms sealed with LUCM
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
75 ms closing with LUCM for control circuit
Mechanical durability 15000000 cycles
Maximum operating rate 60 cyc/mn
[Ui] rated insulation voltage 600 V conforming to UL 508
690 V conforming to IEC 60947-1 (pollution degree 3)
600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
Tightening torque Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm
Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm
Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Width 45 mm
Height 145 mm
Depth 126 mm
Net weight 0.9 kg
Environment
Heat dissipation 2 W for control circuit with LUCA, LUCB, LUCC, LUCD
1.7 W for control circuit with LUCM
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11
Product certifications UL
ASEFA
CSA
GOST
ABS
CCC
ATEX
BV
GL
LROS (Lloyds register of shipping)
DNV
Standards UL 508 type E, with phase barrier
EN 60947-6-2
IEC 60947-6-2
CSA C22.2 No 14 type E
IP degree of protection IP20 conforming to IEC 60947-1 (front panel and wired terminals)
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -25…60 °C with LUCM
-25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage -40…85 °C
Fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
Operating altitude 2000 m
Shock resistance 10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27
4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Non-dissipating shock wave 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2
1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
Immunity to radioelectric fields 10 V conforming to IEC 61000-4-6
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive Compliant
EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 36758442667

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.5 ★★★★★
Based on 871 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
C
Verified Purchase
Chris Mason
Phoenix, US
★★★★★ 5
Fresh Scent
Scent: Aloe & Green Tea
Both the Lavender and the Aloe and the Green Tea scents are light and fresh and perfect for the bathroom, kitchen, or any room in the home.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 20, 2026
G
Verified Purchase
Great size litter box with clicks to keep top in place.
Omaha, US
★★★★★ 5
Smell is so clean
Scent: Ocean Breeze
Love the smell
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026
D
Verified Purchase
Donna V.
Boise, US
★★★★★ 5
Excellent product and value
Scent: Lemon
Crisp light lemon scent; not heavy perfume. Gets rid of odors. Just takes a small spritz.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 10, 2026
D
Verified Purchase
Debbie Burton
Fort Morgan, US
★★★★★ 4
Good product
Scent: Lemon
Door bell was not rang! 11pm we found pkg and unacceptable.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 16, 2024
K
Verified Purchase
Kitkat
Houston, US
★★★★★ 5
Clean, fresh smell
Scent: Lemon
I love these room fresheners. Does the job and leaves a light lemony sent.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 11, 2026

recommand products